Total quantity or scope of tender
Measurement & Control System
There are four meatal hydride (MH) reactors and there are two 3-way valves installed at the inlet and outlet of each MH reactor. The 3-way valves are used to control specified heat transfer medium (hot, cooling or cold water) flowing into each MH reactor.
There is a hydrogen pipe connected between each MH pair and each hydrogen pipe is equipped with one 2-way valve to control hydrogen gas flowing from one MH reactor to another.
There are three water pumps installed in hot, cooling and cold water circuits respectively. The pumps are frequency controlled to control hot water, space and cooling water temperatures separately.
Three water flow meters are installed in the hot, cooling and cold water circuits to measure the water flow rates.
Two hydrogen flow meters are installed in two hydrogen pipes to measure the hydrogen flow rates.
Three power meters are installed to measure the pump power consumptions.
Two safety valves are installed in two hydrogen pipes.
Data log system and PC is needed for the measurements
Capable of remote initiation of self-cleaning programme.
Networkable
Computerized enabling remote monitoring and control
Hardware & Software
Computer software with following facilities:
Batch data
Initializing a batch
Data acquisition <10 minutes full scan
Set point control
Output in graphics or text mode
Compare data between (a) present and old runs (b) old and old runs.
Database of reference data for comparison/identification independent of run conditions
Alarms.
Data export to convenient windows based program.
Comparison with Reference Database
Intelligent sampling control (for differing levels of analyte and contaminant concentration)
Weight <40 Kg.
System components
Suitable for above specification.
High temperature metal hydride reactors (2)
Low temperature metal hydride reactors (2)
High temperature hydride alloys (100 kg)
Low temperature hydride alloys(100kg)
3-way valves(8)
2-way valves(2)
Water pumps(3)
Fuel cell waste heat-water heat exchanger(1)
10 kW Finned-tube water cooler(1)
Space water cooler(1)
The heat source (hot water) temperature =90°C
The cooling medium (water) temperature for heat rejection=30°C
The chilled medium (water) temperature to be produced=5°C
Note: We have got the schematic diagram with design conditions for this proposed system. However, it is a new technology and confidential and it is not appropriate to disclose this information at this stage.
Accessories
Hot water circuit pipes
Cooling water circuit pipes
Cold water circuit pipes
Hydrogen gas pipes(2)
Tees and U-bend connections
|